  • Transformer ON-Load Tap-Changer Tester

    WAYZ-2011 - Wuhan Sangao Electrical Test Installations Limit Co.

    This Transformer on-Load Tap-Changer Tester is acc to Chinese Electric Power Industry Standard, It also can meet the requirement of electrical equipment handover and prevention test standard.To achieve the accurate measurement of on load tap changer's transition time, transition resistance,three-phase synchro nization parameterssyn.It is the best test equipment of on-Load Tap-Changer.

  • Galvanostat and Zero Resistance Ammeter

    ACM Instruments

    This instrument offers a Potentiostat, Galvanostat and Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator in one. It is based around a two Amp Potentiostat teamed with a two Amp Zero Resistance Ammeter and can be supplied as - 6 channel, with six sequential channels, 8 channel (eight sequential channels) or 12 channel (twelve sequential channels). Connection to the controlling Windows PC is via a standard RS232 port, optically isolated for full floating operation. The instrument is supplied with a full set of cables and software, user manual and application notes on CD.

  • Cable Length Meter

    KT-96CR - KILTER ELECTRONIC CO.,LTD

    Range: 60m / 600m / 6km / 60km(197ft-197,000 ft)Resistance: 600mΩ -- 600ΩAccuracy: ±1.5% reading ±3 digits;Resolution:RES Mode 0.01mΩ Cap Mode 0.01mwire guage: 0~26 (ga).material:Al /CuAuto range;Backlight controlResistance & Capacitance measurementSelf- calibrating function;Use a standard cable or a known length cable to calibrate;Auto save the parameter of the cable;Applicable for any type and any size of cable;Transform resistance of wire and capacitance between two wires to length;4-wire vector measurement, high accuracy and resolution.Unit: m / km; ft

  • Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %

    72-7270 CAL D - Tenma

    The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %

    72-7270 CAL DU - Tenma

    The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %

    72-7270 CAL - Tenma

    The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Passive Probes

    Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • Getac Notebook

    Customized X500 - beltronic IPC AG

    The customized X500-MIL notebook unit is based on the X500 unit designed by the manufacturer GETAC for Industrial or Military environments requiring a reliable and robust system. It achieves certification levels military MIL-STD-810G (in terms of resistance to mechanical and thermal environments) and MIL-STD-461G (in terms of compliance with EMC standards) and it can even be certified TEMPEST SDIP- 27 level A, B or C.The customized X500-MIL unit can also be powered directly by an on-board voltage between 12 to 36 VDC while respecting the MIL-STD-1275 standard.

  • Multifunction Electrical Installations Meter

    MPI-520S - Sonel S.A.

    The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.

  • 3 Wire (Digital) Earth Resistance Tester

    2720 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.

  • 3 Wire (Digital) Earth Resistance Tester

    1820 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.

  • 3 Wire (Digital) Earth Resistance Tester

    4120 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.

  • Digital Megohmmeter

    800 - ACL Inc.

    The ACL 800 Digital Megohmmeter is a dependable and easy-to-use audit kit that is designed to test static dissipative surfaces for electrical resistivity and resistance according to industry standards such as ANSI/ESD test methods S4.1, S7.1, and ASTM D257. Tests are easy to perform with or without the 5lb probes. Use optional concentric ring probe for conformance to STM11.11.

  • Automatic Ozone Test Chamber

    EKT-2001OZ - Ektron Tek Co., Ltd.

    Designed and manufactured in accordance with ASTM D1149, ISO1431 & JIS K6259 standards. Providing precise and accurate ozone (O3) concentration environment for rubber and polymer test. Widely applied to (1) Accelerated ageing research (2) Quality control and assurance tests and (3) R&D laboratory formula experiments for cracking resistance.